Additional Product Information
Display Mounting Panel: Black flush mount panel, approximately 4” wide by 2.8” high by 1” deep (102mm wide X 71mm high X 25mm deep). Panel screws to wall. Required cutout size is 3” wide by 1.8” high.
System Power Requirements: Display requires 12 volts from the RV battery, the system will function from 11 volts to 16 volts. Current drain is less than 200mA.
Wiring: A single two wire conductor required from the display to the senders. All the senders are wired in parallel. 12 V power and ground required for display. Single wire required for LPG sender if sender grounded at tank.
Pump Switch: The pump and heater switch is rated for a maximum of 6 amps. A relay is required if more than 6 amps is needed. A 7.5 amp fuse is included.
|
|
|
|
|
|
|