Additional Product Information
The Mode Select Switch: The Charge Wizard functions are fully automatic however, you can test the Charge Wizard’s functions manually by pressing and holding the MODE SELECT SWITCH BUTTON DOWN. When the button is first pressed, the light will be “ON” all the time, indicating it is in the BOOST Mode (converter output 14.4 VDC). If you continue to hold the button, the unit will switch to the NORMAL Mode (converter output 13.6 VDC) and the light will blink from once to many times a second. If you continue to hold the button down the unit will go into the STORAGE Mode (converter output 13.2 VDC) and the light will blink approximately every five- (5) seconds. NOTE: No matter which mode you manually select, the Charge Wizard will automatically return to the NORMAL Mode of operation after 4 -hours.
|