Blue Streak THETFORD AQUA-MAGIC V Installation



INSTALLATION INSTRUCTIONS
THETFORD AQUA-MAGIC® V

1. Remove the stool.

A. Remove two bolts, one on each side.
B. Remove the water line located at the rear of the stool.
( MAKE SURE WATER IS OFF )

2. Locate flush line between vacuum breaker and bowl.

A. Flush line is located to left rear of stool. [Photo View A]

B. Remove Water Module Link and discard. [It is the corrugated line.]
C. Use the two pieces of ½ inch id clear vinyl tubing provided in kit, one 1½ inch long and one 2½ inch long.

D. With the clamps provided, secure the two pieces with the arrow pointing towards the longest. [Photo View B]

E. Insert assembly through the hole [Photo View C] and attach the nozzle assembly. (No clamp needed)

Slide the other end over nipple at the Water Module and clamp. ( [Photo View D]
Snap nozzle assembly in place.

3. Reinstall stool, making sure all gaskets, bolts and water connections are secure.
4. Mounting the dispenser reservoir to the wall.

A. Locate reservoir to the back or side wall providing easy access for filling.
B. Keep reservoir lower than back of stool.
C. Screw reservoir into place with the three screws provided with kit.

5. FINAL CHECK LIST
A. Check water line for leaks.
B. Check stool by flushing.
C. Add a few ounces of
Blue Streak Chemical® to reservoir.
D. Flush stool. Finish filling reservoir.
6. Q: How Do I Winterize the Blue Streak Dispenser?

A: Run the chemical level low [1to 2 inches] in the reservoir and winterize your unit as you would normally. To remove chemical from the reservoir; unscrew the tank from the wall leaving tubing attached to tank and pour chemical into another container.