1. Remove
stool. |
A. Remove two bolts, one on each side.
B. Remove water line located at the rear of stool.
( MAKE SURE WATER IS OFF )
|
|
2.
Locate flush line between vacuum breaker and bowl. |
A. Next separate the top from the bottom.
1. Remove eight (8) screws from under rim.
2. Gently pry apart. [Photo 2A]
|
2A
|
B. Cut a small section out of flush line.
( Between two smooth sections.)
C. Using a hair dryer, warm plastic line so it can
easily slip over T-valve. The arrow on the T-valve
should point toward the bowl.
( THIS IS VERY IMPORTANT )
D. With the two clamps provided, secure T-valve in
place. [Photo 2B-D]
|
2B-D |
E. At the back of the base, drill a 11/32 hole
in the flat section for line supply.
F. Feed line through hole.
( A tight fit is necessary to avoid any leaks.)
[Photo 2E-F]
|
2E-F |
G. Reassemble stool making sure blade
spring is in place.
H. Reattach ¼ line to reservoir. Apply silicone on
stem.
|
|
3. Reinstall
stool making sure all gaskets,
bolts and water connections are secure.
|
4. Mounting
the dispenser on the wall. |
A. Locate reservoir to the back or side of the
wall providing easy access for filling.
B. Keep level or lower than back of stool.
C. Screw reservoir into place with the three screws
provided with the kit.
|
|
5. FINAL
CHECK LIST |
A. Check water lines for leaks.
B. Check stool by flushing.
C. Add a few ounces of Blue
Streak Chemical® to reservoir.
D. Flush Stool. Finish filling reservoir.
|
6.
Q: How Do I Winterize the Blue Streak Dispenser?
|
A:
Run the chemical level low
[1to 2 inches] in the reservoir and winterize your
unit as you would normally. To remove chemical from
the reservoir; unscrew the tank from the wall
leaving tubing attached to tank and pour chemical
into another container.
|